In addition to reporting primary system values, the Link 10 is capable of
many other front panel functions and will also display important historical
battery data. The words below the bar graph display indicate which of
these functions you are accessing. To use these functions you must read
and understand the following section of this manual.

RESET

DATA

LOCK

FUNC

Resetting the Link 10

RESET Resets amp hours to zero and resets the Link 10 to factory values.

To RESET the amp-hour display to zero, SELect the RESET function as
previously described. The letters AH

AH

AH

AH

AH will appear in the display. Press and

hold the SET button. After five seconds the amp-hour display will be reset
to zero and the letters ALL

ALL

ALL

ALL

ALL will appear. If you continue to hold down the

SET for another five seconds all variables and functions are reset to the
factory defaults.

RESET

DATA

LOCK

FUNC

Front Panel Locking

LOCK

Prevents user access to Set Up and Advanced Functions.

To LOCK the Link 10, SELect the LOCK function as previously described.
The letters LOC

LOC

LOC

LOC

LOC will appear in the display, indicating you are in the LOCK

function. Press SET and the letters off

off

off

off

off appear, indicating the front panel

is not locked. Press SET again and the letters on

on

on

on

on will appear, indicating the

front panel is locked. Repeating this procedure toggles the lock off and on.
The display will report off

off

off

off

off or on

on

on

on

on, indicating Lock off or on.