Advanced functions – Xantrex Technology LINK 10 User Manual

Page 31

Advertising
background image

31

F03 DISPLAY OR SET BATTERY TEMPERATURE

If there is no external temp sensor and F16 is OFF (factory default),

this function sets ambient battery temperature used to caluculate rate
corrected
battery capacity which drives the LED bar graph and the
Time remaining display. Feature not available on units with serial

numbers prior to 05000.
DEFAULT: 20 °C

RANGE: 0–40 °C

STEP: 1 °C

If F16 is ON and an optional external temperature sensor is connected
between Pin 6 and Pin 8 (ground), F03 will display temperature
(0–99 °C). Temperature will continue to be displayed until one of the

two front panel buttons is pressed. Active Temperature display is
annunciated by the absence of front panel status indicators. If 0 is
displayed at normal (~ 20 °C) temperatures, an open temperature

probe should be assumed. If >99 is displayed at normal temperatures,
a shorted probe should be suspected.

F04 TURN ON KWHRS DISPLAY

Kilowatt hours are displayed in the Ah mode. (Note: The kWh display

does not take into account Charging Efficiency. As a condition for a
recalculation of the CEF and an automatic reset of amp hours to zero,
100% of the energy removed from the battery must be returned. The

number in the kWh display must be zero or positive to allow a
recalculation of the CEF and an automatic reset to zero. You may use
this function to verify that this condition has been met.)

DEFAULT: OFF

RANGE: OFF or ON

F05 USE ALTERNATIVE ENERGY (AE) DEFAULTS

Changes time to meet Charged Parameters to one minute from the

normal five minutes. (Also consider changing Charged Current to 4%.)

DEFAULT: OFF

RANGE: OFF or ON