Sampling frequency – Yamaha DSP5D User Manual
Page 392

Electrical characteristics
392
PM5D/PM5D-RH V2 / DSP5D Owner’s Manual
Reference section
❏ Dynamic Range
* Dynamic range are measured with a 6 dB/octave filter @12.7 kHz; equivalent to a 20 kHz filter with infinite dB/octave attenuation.
❏ Sampling Frequency
Input
Output
RL
Conditions
Min.
Typ.
Max.
Unit
INPUT 1-48
OMNI OUT 1-24
600
Ω
AD + DA, GAIN: Min
Fs=44.1/48 kHz
108
dB
ST IN 1-4
Fs=88.2/96 kHz
106
—
DA Converter
110
Parameter
Conditions
Min
Typ
Max
Units
External Clock
Frequency Range
Normal Rate
42.9975
49.200
kHz
Double Rate
85.995
98.400
Internal Clock
Frequency
Word Clock: Int 44.1 kHz
44.1
kHz
Word Clock: Int 48 kHz
48
Word Clock: Int 88.2 kHz
88.2
Word Clock: Int 96 kHz
96
Accuracy
Word Clock: Int 44.1 kHz
50
ppm
Word Clock: Int 48 kHz
Word Clock: Int 88.2 kHz
Word Clock: Int 96 kHz
Jitter
Word Clock: Int 44.1 kHz
5
ns
Word Clock: Int 48 kHz
Word Clock: Int 88.2 kHz
Word Clock: Int 96 kHz