Xerox 6204 EN User Manual

Page 135

Advertising
background image

10 Main Menu

Wide Format Copy System User Guide

129

e) Post Test 9 – Pixel Magic Interface

f) Post Test A – Pixel Magic Internal

g) Post Test B – Video Path

h) Post Test C – 24 VDC (Volts Direct Current) Power Supply Test

i)

Post Test D – Lamp

8. Press

the

Start

key to begin the system test. While the tests are executing, the

bottom display line changes to “RUNNING.”

At the completion of the tests, the test results are displayed. If a sub-test is
successful, a “P” is displayed. If a sub-test fails, an “F” is displayed. If an “F” is
displayed, the test has failed and service is required.

9. Press

the

Exit

key to return to the SCANNER DIAGNOSTICS menu screen.

Write NVR

The WRITE NVR option is for use by the Customer Service Engineer only and requires the entry
of the diagnostic password. It allows the Customer Service Engineer to modify the contents of
the non-volatile memory of the Scan System.

Reset NVR Defaults

The RESET NVR DEFAULTS option is for use by the Customer Service Engineer only and
requires the entry of the diagnostic password. It allows the Customer Service Engineer to reset
the NVR values to the factory default values.

Scanner Reliability Meter

Select the SCANNER RELIABILITY METER option to view the current value of the usage meter
maintained by the Scan System. The meter counts and displays the number of linear feet since
the Scan System Fault Log was last cleared. The number of linear feet between fault
occurrences is an indication of the reliability of the Scan System.

To run the SCANNER RELIABILITY METER diagnostic:

1. Press

the

Menu

key. The MAIN MENU screen is displayed.

2. Press

the

Next

key until DIAGNOSTICS is highlighted.

3. Press

the

Enter

key to select DIAGNOSTICS. The DIAGNOSTICS menu screen is

displayed.

4. Press

the

Next

key until SCANNER DIAGNOSTICS is displayed.

5. Press

the

Enter

key to select SCANNER DIAGNOSTICS. The SCANNER

DIAGNOSTICS menu screen is displayed.

6. Press

the

Next

key until SCANNER RELIABILITY METER is highlighted.

7. Press

the

Enter

key to select SCANNER RELIABILITY METER. The SCANNER

RELIABILITY METER screen is displayed.

The Scanner usage meter is intended for gathering data about the reliability of the scanning
mechanism. This meter measures linear usage only. Units are displayed as either feet or meters
depending on the display units selected for the machine. Refer to “Localization” in the “Main
Menu” section for complete information about setting the display units.

Below is an example of the SCANNER RELIABILITY METER screen. In the example, the units
are displayed as feet.