York 090 User Manual

Page 4

Advertising
background image

279104-YTG-B-0307

4

Unitary Products Group

- = Not applicable

COOLING CAPACITY - With Air Handler Coils

UNIT MODEL

AIR HANDLER

COIL

1

MODEL

COOLING

MODEL

ELECTRIC

2

HEAT KW

W

RATED

CFM

NET MBH

SEER

W/O TXV

SEER

WITH TXV

3

EER

TOTAL SENS.

3 PH 10 SEER HP WITH MA / MC / N-AH / G2FD

E1RA036S(25,46)

MA12BN2,4

10

17

FC/MC35B3X

1250

34.4

25.3

10

–

8.95

MA12BN2,4

10

17

FC/MC36B3X

1250

34.4

25.3

10

–

8.95

MA12BN2,4

10

17

FC/MC42B3X

1250

34.4

25.3

10

–

8.95

N1AHC1646

10, 15

21

G2FD042(S,H)21

1250

34.2

25.3

10

–

8.95

E2RA048S(25,46

MA16CN4

10, 15

21

FC/MC48C3X

1600

45.5

33.7

10

–

9.45

MA20DN2

10, 15, 25

24

FC/MC48D3X

1725

45.5

33.7

10

–

9.45

MA20DN4

10, 15, 29

24

FC/MC48D3X

1725

45.5

33.7

10

–

9.45

N1AHC1646

10, 15

21

G2FD048(S,H)21

1600

45.5

33.7

10

–

9.45

N1AHD2046

10, 15, 29

24

G2FD048(S,H)24

1600

45.5

33.7

10

–

9.45

E1RA060S(25,46)

MA20DN4

10, 15, 29

24

FC/MC60D3X

2000

57.0

41.0

10

–

9.80

N1AHD2046

10, 15, 29

24

G2FD048(S,H)24

1700

57.0

41.0

10

–

9.80

3 PH 10 SEER HP WITH AHP / SHP / F2RP / RC / FP / FC

4,5

E1RA036S25

F2RP/FP036

5, 8, 10, 15, 19

21

–

1250

34.0

24.9

10

–

9.00

F2RD/FP042

5, 8, 10, 15

21

–

1250

34.0

25.6

10

–

9.00

AHP36C3X

10, 15

21

–

1250

34.0

25.6

10

–

9.00

AHP42C3X

10, 15, 18

21

–

1250

34.0

25.6

10

–

9.00

E2RA048S25

F2FP048

5, 8, 10, 15, 20, 25

24

–

1600

45.0

33.5

10

–

9.40

F2FP060

5, 8, 10, 15, 20, 25

24

–

1600

46.5

34.4

10

–

9.60

AHP/SHP48D3X

10, 15, 18

24

–

1600

46.5

34.4

10

–

9.60

E1RA060S25

F2FP060

5, 8, 10, 15, 20, 25

24

–

1700

56.0

40.0

10

–

9.40

AHP/SHP60D3X

10, 15

24

–

1700

56.0

40.0

10

–

9.40

Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ARI Standards 210/240.
Cooling MBH based on 8

0°F entering air temperature, 50% RH, and rated air flow.

KW includes compressor, outdoor fan and indoor blower motor watts. Add-on coils include 365 watts/1000 CFM for blower motor.
EER (Energy Efficiency Ratio) is the total cooling output in BTU’s at a 95°F outdoor ambient divided by the total electric power in watt-hours at those conditions.
SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTU’s during a normal annual usage period for cooling divided by the total electric power input
in watt-hours during the same period.

1. G2FD coils available with a factory installed horizontal drain pan. See price pages for specific model number.
2. Single phase units require single phase 2HK heaters.

3. TXV = Use 1TV700 Series Kit.

4. To meet R=4.2 insulation requirements, substitute F2FP for F2RP, and F2FC for F2RC

.

models. All ratings remain the same.

5. FG8, FG9, and FL8 furnaces and F2RP / F2RC air handlers have B.O.D. standard.

Advertising