Service procedures (continued), Replacing battery holder parts – 3M HEADSET C1060 User Manual

Page 13

Advertising
background image

Model C1060 Headset Intercom System

Replacement Parts and Service

©3M 2005 November

13

Service Procedures (continued)

Replacing Battery Holder Parts

Tools Required:

1 – Number 0 Phillips Screwdriver

1 – Soldering iron.


Procedures:

1.
Make sure power is off and remove Battery.

2. Remove two screws and Cover. (If replacing

old style Battery Contacts, discard all Battery
Holder parts, they are not compatible with
newer Battery Holder parts.)

3. Unsolder the two Battery Holder PWA wires.

4. Insert the Headband wires through the holes

from the back side of the replacement Battery

Holder PWA. Solder the RED wire to the

+

connection point and the BLACK wire to the

connection point.

5. Press the Battery Latch Spring onto the top

peg of the Battery Latch. Insert the Latch with
Spring down through the top of the Base as
shown. The beveled bottom edge of the Latch
MUST face the battery.

6. Press the top of the Spring into the small

molded ribs located inside the top of the Base.

7. Insert the Battery Latch Button through the

front of BOTH the Base and Latch. Squeeze
the parts until they snap securely together.

8. Press the Battery Holder PWA onto the pegs

of the Base noting that one hole is larger than
the other.

9. Place the hole in the Headband over the

retaining peg in the Cover. Route the power
wires between the two posts near the top and
the three posts near the bottom as shown. Be
careful to avoid pinching wires while
replacing Cover and two screws.

10. Install new Headband Pad on Battery Holder

Cover.




Battery Latch
Button

Battery Latch

Battery Latch
Spring

Battery Holder PWA

Power Wire
Routing

Advertising