Jotul I570 User Manual

Page 32

Advertising
background image

32

les combustibles recommandés.

Respectez les consignes d'utilisation. Utilisez uniquement

Verwenden Sie nur empfohlenen Brennstoffen.

Montage- und Bedienungsanleitung beachten.

Follow user`s instructions. Use only recommended fuels.

standard

Certificate/

The appliance can be used in a shared flue.

Minimum distance to adjacent combustible materials:

Emission of CO in combustion products

Serial no: Y-xxxx, Year: 200x

Manufacturer:

N-1602 Fredrikstad
Norway

Jøtul AS
POB 1441

Sweden

EUR

Intermittent

Nominal heat output

Norway

Country

Operational type

Fuel type

Operation range

Efficiency

Klasse II

Classification

Standard

Flue gas temperature

Room heater fired by solid fuel

Product:

Jøtul

SP Sveriges Provnings- och

221546

Forskningsinstitut AB
SP Swedish National
Testing and Research
Institute

:

Approved by

:

:

:
:

:
:

:

Minimum distance to adjacent combustible materials:

OGC

SP

EN

Serial no.

Table of contents

Installation manual with technical data

1.0 Regulatory information .................................. 32
2.0 Technical data ................................................. 32
3.0 Installation ..................................................... 34
4.0 Servicing .......................................................... 38
5.0 Optional Equipment ....................................... 38

General use and maintenance manual

6.0

Safety

precautions

7.0 Choice of fuel

8.0

Use

9.0

Maintenance

10.0 Operational problems - troubleshooting

On all our products there is a label
indicating the serial number and
year. Write this number in the
place indicated in the installation
instructions.

Always quote this serial number when
contacting your retailer or Jøtul.

1.0 Regulatory information

Installation of a fireplace must be according to local codes and
regulations in each country.

All local regulations, including those that refer to national and
European standards, shall be complied with when installing
the product.

Both an installation manual with technical data and a general
user and maintenance manual accompany the product. The
installation can only be taken into use after it has been checked
by a qualified inspector.

An approval label made of heat resistant material is located
on the heat shield at the back of the product. This contains
information about identification and documentation for the
product.

2.0 Technical data

Material: Cast

iron

Finish: Black

paint

Fuel: Wood
Log length, max.:

55 cm

Flue outlet:

Top

Flue dimension
(outside the outlet) :

Ø 200 mm/314 cm

2

cross section

Approx. weight:

220 kg

Optional extras:

Decorative frame, internal ash

solution
Dimensions, distances etc.: See fig.1

Technical data according to EN 13229
Nominal heat output:

14,0 kW

Smoke gas mass flow:

13,2 g/s

Recommended chimney draught: 12 Pa
Effiency: 77%@14,0

kW

CO emission (13% O

2

): 0,12

%

Flue gas temperature:

265

0

C

Operating mode:

Continuous

Wood consumption

The efficiency of Jøtul I

570 gives it a nominal heat output of 14,0

kW. Wood consumption, at nominal heat output: Approx. 4,0
kg/h.
The size of the pieces of wood should be:

Kindling (finely split wood):
Length: approx. 30 cm
Diameter: 2-5 cm
Quantity required each time: 6 - 8 pieces

Wood (split wood):
Recommended length: 30 - 50 cm
Diameter: Approx. 12 - 15 cm
Interval for adding wood: Approx. every 65 minutes
Fire size: 4,3 kg (nominal output)
Quantity required each time: 4 pieces

Nominal heat output is achieved when the ignition vent is
approx. 30 % open (fig.12 B) and the air vent is 60% (fig. 12 A).