Aluminium composite milling machine
Technical data

PF 1200 E

Power 1200

W

Speed (no load)

2000 - 5500 rpm

Milling tool
- outside diameter

118 mm

- drill hole diameter

20 mm

- width

14 mm

Weight (excluding cable)

5.4 kg

Degree of protection

/ II

The specifi ed illustrations can be found at the
beginning of the operating instructions.

Graphical symbols

Caution. Danger!

Read the operating instructions/notes

Wear ear protection!

Wear protective goggles!

Wear a protective mask!

1 Intended

use

The PF 1200 E is used to route grooves into com-
posite plates made from aluminium, plastic, min-
eral materials, and other similar materials.

The user is liable for damage and injury

resulting from incorrect usage!

2 Safety

instructions

2.1

General Safety Rules

WARNING! Read all safety warnings

and all instructions. Failure to follow
the warnings and instructions may result
in electric shock, fi re and/or serious in-
jury.

Save all warnings and instructions for future
reference.
The term „power tool“ in the warnings refers
to your mains-operated (corded) power tool or
battery-operated (cordless) power tool.

2.2 Tool-specifi c safety rules
- Only use the tools supplied by Festool for the

machine. Do not fi t other tools into the machine
for safety reasons. Do not use tools with blunt
or damaged cutting edges.

- Ensure that the milling tool is fi rmly seated and

check that it runs smoothly.

Wear suitable personal protection

equipment: Ear protection to
reduce the risk of damaging your
hearing; Protective goggles; Face
mask to reduce the risk of inhal-
ing harmful dust; Protective
gloves when handling tools and
coarse materials

2.3

Noise and vibration information

The typical values determined in accordance with
EN 60745 are:
Sound-pressure level

91 dB(A)

Sound-power level

102 dB(A)

Measuring uncertainty allowance

K = 3 dB

Wear ear protection!

Vibration emission value a

h

(vector sum for three

directions) and uncertainty K measured in accord-
ance with EN 60745:

a

h

= 3,0 m/s²

K = 2,0 m/s²

The emission values specifi ed (vibration, noise)
were measured in accordance with the test con-
ditions stipulated in EN 60745 and are intended
for machine comparisons. They are also used for
making preliminary estimates regarding vibration
and noise loads during operation.
The emission values specifi ed refer to the main
applications for which the power tool is used. If
the electric power tool is used for other applica-
tions, with other tools or is not maintained suf-
fi ciently prior to operation, however, the vibration
and noise load may be higher when the tool is
used. Take into account any machine idling times
and downtimes to estimate these values more
accurately for a specifi ed time period. This may
signifi cantly reduce the load during the machine
operating period.

3

Power supply and start-up

The mains voltage must correspond to

the specifi cation on the rating plate.

Switch (4.2) serves as an On/Off switch (press =
ON, release = OFF). The switch can only be activat-
ed after the switch lock (4.1) has been pushed up.
Activating the switch lock simultaneously locks
the plunging equipment and the milling unit can
be moved down against the spring force. This
causes the milling tool to emerge from the pro-
tective cover.