Festool CTL 22 E SG User Manual

Page 13

Advertising
background image

13

- The appliance may be operated only in an

adequately ventilated space (in compliance

with national industrial safety provisions).

- Do not suck in any sparks or hot chippings.

- With the exception of wood dust, do not

suck in any fl ammable or explosive dusts

such as magnesium, aluminium etc. - Risk

of explosion!

- Do not use to extract fl ammable or explo-

sive liquids (e.g. petrol, thinners) - Risk

of explosion!

- Do not use to extract aggressive liquids/

dry materials (e.g. acids, alkalis, solvents).

- Remove plug from mains socket when not

in use and before maintenance work.

- Do not pull plug out of mains socket by

its cable.

- Protect the cable against heat, oil and

sharp edges.

- Check the plugs and cables regularly and

have them replaced by an expert if damaged.

- Do not leave devices out in the rain.

- Do not lift or carry the devices by their

handles using a crane hook or lifting gear.

- The device may only be used by persons

who have been trained in its use and who

are authorised to do so.

- If noxious dusts have been extracted, the

vacuum cleaner and all accessories must

be completely cleaned (inside and outside)

by suction and wiping, before removal

from the contaminated area. Parts that

cannot be completely cleaned are to be

packed for transport in a plastic bag with

an airtight seal.

- For safety reasons, only operate the ma-

chine using a totally earthed socket.

3

Appliance preparation and initial

operation

The accessories are delivered horizontal in

the container (2.10), and must be removed

prior to initial operation.
3.1 Power

supply

The line voltage and frequency must

correspond with the data on the rat-

ings plate!

Make sure that the vacuum cleaner is switched

off when you plug the power cable in.

The antistatic system (AS)

Friction in the suction hose causes electro-

static charges which can result in unpleas-

ant electric shocks for the operator. In order

to conduct these static charges to earth,

the extraction units are provided with an

antistatic system as a standard feature.

However, antistatic hoses and accessories

have to be used in this case. The antistatic

function will only work if the plug is plugged

into a totally earthed socket.
3.2

On/off switch (1.3)

In position 0 the vacuum cleaner is switched

off and the appliance plug socket (1.2) is dead.

Two modes of operation are possible:

a)

Switch position „MAN“

The appliance plug socket is dead.

The cleaner motor starts immediately.

b)

Switch position „Auto“

The appliance plug socket is live.

Before turning the switch to the

„Auto“ position, ensure that the

tool connected to the appliance plug

socket is switched off.

The cleaner motor starts only when the tool

connected to the appliance plug socket is

switched on.
3.3

Suction force regulator (1.4)

The suction force regulator can be used to

vary the suction capacity. This permits a

precise adaptation to different substances

to be picked up.
3.4 Temperature

control

A temperature fuse switches the dust ex-

tractor off before this reaches a critical

temperature to protect against overheat-

ing - switch dust extractor off and leave for

around 5 minutes to cool down.

If the dust extractor still cannot be switched

back on, please consult a Festool-service

centre.
3.5

Connecting an electric tool

Observe the maximum connected

load on the appliance plug socket

(see “Technical Data“)!

Make sure that the electric tool is

switched off when plugging it in and

unplugging it.

Connect the electric tool to the appliance

plug socket (1.2).
3.6

Connecting pneumatic tools

Make sure that the pneumatic tool

is switched off when plugging it in

and unplugging it.

When the compressed-air module (1.8)

(452829; supplied ready with CTL 33 LE

SG and CTL 44 LE) is fi tted, the automatic

Advertising
This manual is related to the following products: