Icons and symbols, Trouble shooting – RIDGID CountPlus User Manual

Page 12

Advertising
background image

Ridge Tool Company

0

Tools For The Professional

TM

SeeSnake

®

CounTPluS Cable-CounTeR

Damage to the product that requires service. Refer servicing to quali-

fied service personnel under any of the following conditions:

o If liquid has been spilled or objects have fallen into product;

o If product does not operate normally by following the operating

instructions;

o If the product has been dropped or damaged in any way;

o When the product exhibits a distinct change in performance.

If you have any questions regarding the service or repair of this machine,

contact Ridge Tool Europe via www.ridgid.eu, your local RIDGID repre-

sentative or local distributor.

In any correspondence, please give all the information

shown on the nameplate of your CountPlus, including
model number and serial number.

Icons and Symbols

Key Pad

Menus

Measurement Display

On/Off

Menu Icon

Menu Key

Slide Edit Screen

Zero/Select Key

Information Screen

Time/Date Display

On/Off

Tools Menu

Down Arrow

Time Settings

Up Arrow/Edit Key

Date Settings

Left Arrow

Measurement Unit

Settings

Right Arrow

Reel and Cable

Settings

Text Key

Figure 19: Icons and Symbols

Trouble Shooting

PROBLEM

PROBABLE

FAULT

LOCATION

SOLUTION

Camera video

image not seen.

No power to

SeeSnake connector.

Check power is correctly

plugged in.

Check switch on SeeSnake

monitor.

Connections faulty.

Check alignment and pins

of connection to monitor or

DVR unit from SeeSnake.

Check orientation, seating,

and pin condition in the

CountPlus connection.

CountPlus battery low. Replace 3-volt battery in the

CountPlus (CR2450).

Count accuracy

seems

unreliable.

Settings incorrect for

reel or cable being

used.

Verify the settings are correct

for the SeeSnake cable

length, cable diameter and

reel type you are using.

Counting from a zero

point other than the

one intended.

Confirm you are measuring

from the intended zero-point.

Low Battery

warning

appears.

Battery dead or near-

dead.

Replace 3-volt battery in the

CountPlus (CR2450).

The symbol “+”

appears after

the on-screen

distance

measurement.

Physical cable meas-

urement has exceeded

the cable parameter in

settings.

Verify the actual length of

your installed cable; re-set

the reel and cable settings

for the correct reel type and

actual cable length and diam-

eter as described on page 5.