1.1 Unit description

The SHW 200 - 400 S floor-standing water
heater can provide hot water to suit
requirements up to about 80 °C and supply
one or more draw-off points. The water is
heated electrically.

Stepless temperature adjustment possible
from about 35 °C to about 80 °C

A

(1).

If required, the hot water temperature
limitation set at the works (60 °C) can be
altered by the qualified installer at the
electrical heating element

G

.

The water content is heated to the preset
temperature in accordance with the
operating mode.
Single-circuit operation:
Automatic reheating takes place as a
function of the electricity supply.
Dual-circuit operation:
In this operating mode the appliances
provide basic heating, which automatically
heats up the water content during off-peak
periods.

Rapid heating can be switched on if
required by pressing the button (3). Once
the preset temperature has been reached,
the rapid heating mode will be switched
off, and not switched on again.

The time required for heating up depends
on the cylinder content, the temperature
of the cold water, and the heating capacity.
See the diagram

B

for the heating-up

time at a setting of 60 °C (E) and a cold
water temperature of 10 °C.

1.2 The main points in brief

Temperature selector button (1)
Thermometer (2)
Button for switchable rapid heating mode
(3)
Anode wear display (4)

Operation
Temperature selector button

!

= Cold (see also note on „Freezing

risk“)

I = approx. 40 °C

E = approx. 60 °C (recommended

energy saving setting, low
limescale formation)

III = approx. 80 °C (maximum settable

temperature).

The temperatures may deviate from the
reference values given due to the
particular features of the individual
system.

1. Operating instructions

for the user and qualified installer

1.3 Safety instruction

A hot water temperature of more
than 60 °C may occur at the draw-

off fitting.
Accordingly, keep small children away
from the fittings. Risk of scalding!

1.4 Important instruction

Arrange for the floor-standing water heater
and the safety group to be checked
regularly by a qualified installer.

The appliances are under water mains
pressure. During heating, expansion water
will drip out of the safety valve. If water
continues to drip after the heating phase
has ended, please inform your qualified
installer.

The steel cylinder is fitted on the inside
with a special enamel coating to protect it
against corrosion, and also has a protective
anode with a wear display (signal anode).
Once the signal anode has worn away,
moisture will pass to the display element
(4) and cause it to change colour.

If the display element (4) turns red,
please inform your qualified installer

so that he can check the signal anode and
replace it if necessary.

Risk of freezing
At the temperature selection setting ! (=
cold), and under voltage supply, the appliance
is protected against freezing, but not the cold
water feed pipe or the water mains pipe.

1.5 Trouble-shooting

See „3. Fault elimination - User“

1.6 Care and maintenance

Maintenance work, such as checking
the electrical safety, may only be

carried out by a qualified installer.

At high temperatures almost all water
precipitates limescale. This forms deposits
in the appliance and affects its function and
service life. The heating elements must
accordingly have the limescale removed
from time to time.
The qualified installer, who is familiar with
the quality of the local water, will advise
you of the time for the next maintenance
inspection.

A damp cloth is sufficient for caring for the
plastic components. Do not use any
abrasive or scouring cleaning agents.

1.7 Instructions for
installation and use

Keep these instructions in a safe
place, and give them to the next user

in the event of a change of ownership. In
the event of any maintenance or repair
work being required, provide them to the
qualified installer for his reference.

1.8 Technical data

(the data on the unit rating plate are applicable)

Type

SHW 200 S

SHW 300 S

SHW 400 S

Weight, empty

kg

65

77

90

Contents

l 200

300

400

Max. flow volume

l/min

30

38

45

Permissible operational flow rate

0.6 MPa (6 bar)

Test mark

See appliance rating plate

Electrical connection

See appliance rating plate

Table 1

Dimensions

Ø a mm

630

700

750

C

b mm

730

815

865

c mm

340

365

375

(Hole diameter) Ø e mm

430

490

540

h mm 1570

1585

1755

k mm 1035

1040

1160

l mm

350

390

410

m mm

60

55

55

n mm

80

75

75

Advertising