Installation specification, 2 fault conditions, 3 data table – STIEBEL ELTRON SB AC с 08.06.2009 User Manual

Page 22

Advertising
background image

22

| SB S | SB AC

www.StieBel-eltron.CoM

inStAllAtion

SpeCifiCAtion

15.1.5 SB 650/3 AC

1305

965

450

1850

1725

1480

1135

560

125

125

750

690

50

950

c01

d33

c10

d34

c06

i02

i03

i04

i18

D

00000

17

58

7

SB 650/3 AC

c01 Cold water inlet

Male thread

G 1 1/2 A

c06 DHW outlet

Male thread

G 2 A

c10 DHW circulation

Male thread

G 1/2

d33 Heat source flow

Male thread

G 3/4 A

d34 Heat source return

Male thread

G 3/4 A

h43 Thermometer

Male thread

G 1/2 A

i02 Flange I

Diameter

mm

280

Pitch circle diameter

mm

245

Screws

12 x M14

Torque

Nm

85

i03 Flange II

Diameter

mm

280

Pitch circle diameter

mm

245

Screws

12 x M14

Torque

Nm

85

i04 Flange III

Diameter

mm

280

Pitch circle diameter

mm

245

Screws

12 x M14

Torque

Nm

85

i07 Electric emergency/booster

heater

Female thread

G 1 1/2

i18 Protective anode

15.2 Fault conditions

In the event of a fault, temperatures of up to 95 °C at 0.6 MPa
can occur.

15.3 Data table

SB 302 S

SB 402 S

SB 602 AC

SB 1002 AC

SB 650/3 AC

185354

185355

071554

071282

003039

Hydraulic data

Nominal capacity

l

300

400

600

1000

650

Application limits

Max. permissible temperature

°C

110

110

110

110

110

Max. permissible pressure

MPa

1.0

1.0

1.0

1.0

1.0

Test pressure

MPa

1.5

1.5

1.5

1.5

1.5

Max. flow rate

l/min

38

45

50

70

50

Versions

Sealed unvented type

Dimensions

Height

mm

1585

1755

1685

2525

1725

Width

mm

700

750

750

750

750

Depth

mm

700

750

800

800

830

Weight

Weight (full)

kg

401

519

754

1212

840

Weight (empty)

kg

101

119

154

212

190

Advertising