2.6 Installation location

The DHF ... C compact control is to
be installed vertically in accordance

with

A

(over-sink or under-sink) in a

closed, frost-free room, as near as possible
to the tap point (a dismantled unit is to be
stored in frost-free conditions, since resi-
dual water always remains in the unit).

2.7 Preparing for unit instal-

lation

B

Turn locking cap (3) to the left and with-
draw.
Unscrew cover securing screw and re-
move device cover.

– Detach mounting bracket (19) from the

unit.

– Thoroughly flush through the cold water

supply pipe.

– In the case of a replacement installation,

the available cold water 3-way three-way
isolating valve (

D

, 6) can if necessary be

used.

– With the help of the template (separate

this from the operating and installation
instructions), determine the position of
the cable entry (concealed connection)
and the mounting bracket (19).

G

Cut the electrical connection cable to
length and strip.

C

Secure the mounting bracket.
When replacing DHF/DHA old models
(height 370 mm), the available drilled
securing holes (20) can be used.

– Secure the unit to mounting bracket with

the screwed sleeve (14). Using the nut
on the threaded bolt (21), unevennesses
in the wall, caused for example by mis-
aligned tiles, can be compensated for
(maximum 12 mm).

2.5 Technical data

(the data on the unit rating plate are applicable)

Water connection

G ½ (external thread)

Electrical connection

3/PE ~ 400 V

1/N/PE ~

220/230 V

Max. system-impedance

Z max.

0.14

Protection mode to

EN 60529

IP 24

Typ

DHF 13 C DHF 15 C DHF 18 C DHF 21 C DHF 24 C DHF 12 C1

compact compact compact compact compact compact

control

control

control

control

control

control

Heat output

220V 230V

Partial power Stage !kW

6.6

7.5

9

10,5

12

8

8.8

Rated power Stage!!kW 13.2

15

18

21

24

12 13.2

Rated powe

Stage

!

l/min

3.0

3.0

3.9

4.4

4.9

3.0

Stage !! l/min

4.5

4.5

5.9

6.4

7.6

4.5

Flow rate limit

l/min

6.5

6.5

7.0

7.5

8.0

6.5

Pressure loss *

bar 0.55

0.55

0.6

0.6

0.7

0.55

Flow rate

l/min

4.5

4.5

5.9

6.4

7.6

4.5

Rated capacity

0,6 l

Type of construction

Closed

Rated overpressure

1 MPa (10 bar)

Weight

4,0 kg

Protection class to

DIN EN 60335

1

Test mark

See unit rating plate

Table 3

* Pressure drop values also apply to the minimum flow pressure in accordance with

DIN 44851 / Flow rate for heating from 10 °C to 55 °C (

∆ ϑ

45 K). A pressure drop of

0.1 MPa is recommended for pipe network dimensioning, in line with DIN 1988 Part 3,

Table 4.

Heating element

Copper tubular heating element

Cold water inlet

20 °C

Use in waters

Total alkaline earths

2.5 mol/m³

Overall hardness (earlier unit)

14 °d

Hardness range (earlier unit)

Inclusive of 2 (medium hard)