Fault finding, Environment and recycling 5. guarantee – STIEBEL ELTRON DHF .. C 22.04.2002 - 31.01.2004 User Manual

Page 16

Advertising
background image

16

Fault

Cause

Remedy

Unit does not switch on.

– Water pressure in cold water pipe too

low.

– Descale or replace showerhead/Perlator®.

4. Fault finding

- qualified installer

– Strainer in 3-way valve (6) fouled.

– Clean strainer (

D

, 22).

Differential pressure switch (10, control

valve MRC) with flow rate controller does

not switch on in spite of the hot water tap

being turned fully on.

– Clean strainer (

D

, 22).

– Necessary switch-on quantity to switch on

the heating output is not reached.

– Check water pressure.

Please help us to protect the environment by

disposing of the packaging in accordance with

the national regulations for waste processing.

6. Environment and

recycling

5. Guarantee

Unit does not produce hot water in spite of

an audible switch-on noise by the differential

pressure switch.

– Safety temperature limiter (12) has

tripped, possibly due to:

Check intlet temperature.

a)

Intlet temperature too high.

b)

Control valve (MRC) faulty

.

Check and if necessary replace control

valve. Press reset button

(13).

Heating system does not heat water.

– No voltage.

– Heating system faulty.

– Check fuse (house installation).

– Replace tubular heating element heating

system (11).

Table 5

For guarantees please refer to the pespective

terms and conditions of supply for your

country.

The installation, electrical connection

and first operation of this appliance

should be carried out by a qualified

installer.

The company does not accept liability for

failure of any goods supplied which accor-

dance with the manufacturer's instructions.

c)

Element scaled up

.

3. Fault finding

- user

Not hot water.

The heating element in the DHF ... C

compact control does not switch on despite

a fully opened hot water fitting.

– No power supply.

– Check fuses in the domestic system.

– The necessary switch-on quantity has not

been reached. Dirt accumulation or lime

scale blockage of the Perlators in the

fittings or the shower heads.

Fault

Cause

Remedy

Table 4

– Clean and/or descale.

De-scale or replace element.