English – Vitek VT-1763 User Manual

Page 5

Advertising
background image

5

ENGLISH

REMOTE CONTROL (17)
For convenient control of the unit, use the
remote control.
If there is an isolation insert in the battery
compartment, remove it, if the battery is
supplied separately, remove the holder of the
battery, by preliminary pressing the clamp,
insert the battery in the holder, strictly fol-
lowing the polarity, insert the battery holder
into the remote control. The distance from
the remote control to the humidifier shall not
exceed 5 meters and the angle of 30°.

Correspondence of the remote control
buttons to the buttons on the control
panel of the unit:
29. Power on/off button - (6).
30. Timer setting button – (5).
31. Steam-out intensity button - (1).
32, 33 Indoor humidity setting buttons - (2),

(3).

34. Ionization mode on/off button - (4).

CLEANING AND CARE
Warning: Always switch off and unplug
the unit before cleaning it.

Hard water causes the appearance of scale
on the “nebulizer”, on the inner parts of the
body and on the water tank; it leads to im-
proper operation of the unit and appearance
of white deposit on the interior. In order to
avoid it, it is necessary to clean the nebulizer
every day and replace water as often as pos-
sible, as well as to perform cleaning of the
filter-cartridge (13).
If you are not going to use the unit for a long
time: - pour out water from the tank and the
operating chamber of the “nebulizer”, wash
the water tank, wash and clean the operating
chamber of the “nebulizer” and the “neb-
ulizer” itself, dry the unit and put it away for
storage.

Weekly care
• Once a week carefully wash the water tank

(11) and the operating chamber under the
tank(11) with a neutral washing liquid so-

lution. After that, carefully rinse them with
water.

• Add 5-10 drops of the cleaning agent on

the “nebulizer” (15); wait about 2-5 min-
utes. Use the brush (18) to remove the
deposit from the surface of the “nebulizer”
(15).

Note: As a cleaning agent for the “neb-

ulizer” you can use substances for
scale removal in kettles.

• Do not immerse the unit into water or other

liquids.

Cleaning the filter
• Clean the filter (13) when there are first

signs of a “film” on the furniture items.

• Take the handle (10) and remove the water

tank (10) from the body of the unit (16).

• Turn over the water tank (11), unscrew the

lid (14) by turning it counterclockwise and
remove the filter-cartridge (13), by turning
it counterclockwise.

• Wash the filter-cartridge (13) with running

water and put it for 50-60 minutes into the
bowl with salt solution (2-3 table spoons
for 0,5 liter of water), put off the cartridge
and wash it with running water.

• Place the filter-cartridge (13) back on the

lid (14), by turning it clockwise.

Replacement of the filter-cartridge (13)
Replace the filter-cartridge (13) when nec-
essary.

Storage
- If you are not going to use the unit for a

long time, make sure that all its parts are
dry, including the operating chamber of
the “nebulizer”.

- Do not store the device with water in the

operating chamber.

- Before you put the filter-cartridge away for

storage, clean and dry it, keep the filter-
cartridge in a cool dark place.

Store the humidifier in a dry cool place out

of reach of children.