Removing the Camera from the Marine Case

"

Thoroughly rinse the marine case in a

container filled with fresh water.
Push the buttons while the marine case

is submerged and rinse the dirt out

from any gaps or grooves.

If the marine case was used in seawater,

submerge the marine case in fresh

water for at least 1 hour to remove salt.

#

Take the marine case out of the water and wipe off water droplets on

the case surface using a dry cloth.

$

Open the front lid and remove the camera.

Caution

Turn the buckle with the front lid facing up. The camera may fall out if

the buckle is opened with the front lid facing down.

Make sure that water droplets from parts such as the buckle and O-ring

do not get inside the marine case.

If you cannot avoid opening the marine case at the diving location,

pay attention not to let water droplets from your hair or your body get

inside the case.

Maintenance on the Marine Case

"

Remove the O-ring.

Use a pick to remove the O-ring

to prevent the O-ring and O-ring

groove from being damaged.

#

Wipe off any sand, dust, or other

foreign matter from the O-ring.
Clean up the O-ring groove as

well.

Gently bend the O-ring to check

for any cracks in the O-ring.

Pick

O-ring

O-ring groove

Cracks