Installation: "gas connection, Changing the gas type, Changing the jets – Candy PLDAS 640 X User Manual

Page 6

Advertising
background image

2 4

• CHANGING THE GAS TYPE :

the calorific power output and gas pressure will

vary according to the gas supply. Burner setting must be carried out once the gas and
electrical installation is complete.

When changing gas type, you must follow the procedure below :

. fit the correct jets,
. adjust the appearance of the flame by regulating the air ring.
. adjust the minimum flame on the taps (see page 30).

• CHANGING THE JETS

:

Each jet is designated by size. A special spanner supplied with the appliance is designed to
hold the jets securely during the set up operation.

To gain access to the jets :
. remove the pan supports,
. remove the burner cap and body,
. using the spanner supplied with the appliance, unscrew
the jet,
. fit the correct jet for the type of gas to be used,
. secure the het tightly,
. replace the burner body, cap and the pan support.

INSTALLATION: "GAS CONNECTION"

Jet

Burner
body

Example : Fast or Double ring gas burner 3,2 kW

G20-20 mbar / G25-25 mbar

G30 28-30 mbar

G31 37 mbar

Jet

96

Jet

122

Jets

94 x 2

Jet

96

Jet

61

Jet

80

Jets

65 x 2

Jet

61

1,45 kW

2,5 kW

3,2 kW

1,45 kW

Fast

or

Double ring

Semi-

fast

Semi-

fast

Fast

Jet

122

Jets

94 x 2

Jet

96

Jet

80

Jets

65 x 2

Jet

61

2,5 kW

3,2 kW

1,45 kW

Fast

Semi-

Fast

Fast

4 gas burners

3 gas burners + 1 hot plate