Installation: "gas connection, Setting the appearance of the flame – Candy PLDAS 640 X User Manual

Page 7

Advertising
background image

2 5

• SETTING THE APPEARANCE OF THE FLAME

1. Regulating the air ring on the hob burners : the setting is important as it ensures the
correct combustion and enables the burners to work at maximum efficiency. The table
refers to the value "X" in mm ; it may be necessary to regulate this by plus or minus 1 mm
to obtain a perfect flame.

2. To gain access to the air rings on the hob burners: remove the pan support, the burner
cap and body of the relevant burner. The air ring is located at the lengthening of the burner
unit which is fixed by a screw (see drawing).
If necessary :

. unscrew the screw that holds the air flow adjuster,
. set the correct distance according to the air adjuster protrudes,
. secure the screw when the operation is completed.

INSTALLATION: "GAS CONNECTION"

Quota

X

Air ring

A i r
ring

Semi-fast burner 1,45 kW
or Fast burner 2,5 kW

Fast burner 3,2 kW and

Fast double ring 3,2 kW

Quota

X

Quota "X" in mm of the air ring according to the gas setting

Screw

Screw

G20-20 mbar
G25-25 mbar

G30 28-30 mbar

G31 37 mbar

6

10

14

6

6

10

15

6

0

0

0

0

7

9

14

7

0

0

0

0

7

9

15

7

Fast

Semi-fast

Fast

Semi-fast

Double

ring

Semi-fast

Fast

Semi-fast

Fast

Fast

Semi-fast

PA - PSA 640/2
PLA - PLAS 640

PLA 631

PLDA 640
PLDAS 640