Installation, Technical characteristics, Applying the sealant – Candy PR 2250 GH User Manual

Page 19: Instructions for the installer

Advertising
background image

35

INSTALLATION

Instructions for the installer

The Purchaser is responsible for the installation of the hob. The Manufacturer does not
accept any responsibility for any damage or loss resulting from incorrect installation,
and as such this will not covered by the Manufacturer’s Guarantee.
The hob may be installed in any worktop which is heat resistant to a temperature of
100° C, and has a thickness of 25 - 40 mm. The dimensions of the insert to be cut out
of the worktop are in shown in Fig. 1.

If the Hob is fitted next to a cabinet on either side,
the distance between the Hob and the cabinet
must be at least 150 mm (see Fig. 2); while the
distance between the hob and the rear wall must
be at least 55 mm.
When there is an accessible space between the
built-in hob and the cavity below, a dividing wall
made of insulating material should be inserted
(wood or a similar material).
The wall should be at least 10 mm away from bot-
tom of the drawer. (fig. 2)

The Hob unit is fitted by attaching the Fixing Clamps supplied, using the holes at the base
of the unit.

Applying the sealant

Important - The diagram below shows how the sealant should be applied.

This appliance has been designed for non-professional, i.e. domestic, use.

Appropriate checks and tests have ensured that, even in the most extreme conditions,
the temperatures reached are within acceptable limits. The Hob is thermally insula-
ted (in line with Regulation EN) and may be installed: next to panels higher than
the worktop, for type «Y», or next to panels not higher than the worktop for type
«X». See technical characteristics table «Degree of protection».

Fig. 2

Partition panel

50 mm

min.

30 mm

10 mm

34

TECHNICAL CHARACTERISTICS

* Some models only ** Manufacturer setting

IE cat. II

2H3 +

GB cat. II

2H3 +

Cooking hobs 60x50

A

A

B

B

Burners

4 gas

4 gas

3 gas

3 gas

1 electric 1 electric

Reference type

PL01

PL02

PL01

PL02

Supply Voltage

(V/Hz)

230/50

230/50

230/50

230/50

Installed electric power

(W)

1400

1400

Medium burner

1

1

Large back burner

1

1

1

1

Small burner

1

1

1

1

Large front burner

1

1

1

1

Double ring burner

Maxi burner

Power of gas installed:
- G20/20 mbar (kW)**

8,2

8,2

6,7

6,7

- G30/28-30 mbar (g/h)

597

597

488

488

Electric ignition*

yes

yes

yes

yes

Gas safety device

yes

yes

Product size

mm.

595x510

595x510

595x510

595x510

Degree protection

Type Y

Type Y

Class

3

3

3

3

Fig. 1

Fig. 1b

MD

L

L

S

E

L