Every

has been thoroughly tested and has been shipped in perfect operating condition.

Carefully check the shipping carton for damage that may have occurred during shipping. If the carton
appears to be damaged, carefully inspect your controller for any damage and be sure all equipment
necessary to operate the unit has arrived intact. In case damage has been found or parts are missing, please
contact us or your nearest dealer/distributor for further instructions.

X-Power-HP-Pro

Caution!

There are no user serviceable parts inside this unit. Do not attempt any repairs yourself, doing so will void
your manufactures warranty. In the unlikely event your unit may require service, please contact Acclaimlighting
customer support.

1.1 Unpacking

Do not discard the packing carton in the trash. Please recycle when ever possible.

1.2 Safety Warnings

The ground connection should be essential for this unit.
Do not make any inflammable liquids, water or metal objects enter the unit.
To prevent or reduce the risk of electric shock, DO NOT OPEN THE TOP COVER.
This unit must be operated by adults, do not allow children to play with it.

Always consult authorized personnel for any repairs and maintenance.

There are no user serviceable parts inside this unit. Do not attempt any repairs yourself.
Should you experience any problem during use, please contact your local dealer immediately.
Do not discard the shipping carton in the trash. Please recycle when ever possible.

When unpacking, please check the unit is not damaged. Should something wrong happen to this product,
contact the local dealer immediately.
All rights reserved. No part of the manual included with this product may be reproduced, transmitted,
transcribed or translated into any language in any form, by any means, without authorized permission.

-1-

To optimize performance of this product, please read instructions in this manual and on the case of this
product carefully to familiarize yourself with the basic operations. Once manual has been thoroughly read,
we recommend you should file it for future reference.

1.General Information

1 X-Power-HP-Pro
1 Instruction Manual
1 Screwdriver

You should be in possession of the following items:

The socket-outlet shall be installed near the equipment and shall not be easily accessible

Le socle de prise de courant doit être installé à proximité du matériel et doit être
aisément accessible.

1.) RGB Output Mode is engaged by flipping the dip-switch 4 and 5 to the "OFF" position, one output with
R.G.B. Control is controlled by three channels separately.

In the function, user can flip the dip-switch 5 & 6(6-way Mode Dip Switch) to sel the desired Output Loading
Mode.

5.2.5 Output loading Mode Setting

1

2

3

4

5

6

1

Red+

White +

Warm White +

Blue +

2

Red -

White -

Warm White -

Blue -

OUTPUT TERMINALS

3

Green +

White +

White +

Red +

4

Green-

White -

White -

Red +

5

Blue +

White +

Warm White +

Green +

6

Blue -

White -

Warm White -

Green -

OUTPUT

4

5

1 =ON

0=OFF

00

RGB

10

WHITE

01

WHITE&WARM

11

RGB

-6-

5.2.4 Output Group Mode Setting

In the function, the dip-switch 1& 2 (6-way Mode Dip Switch)is used to set your desired Output Group mode.

MODE

00

1 Group

10

2 Group

01

3 Group

11

6 Group

1

2

1 =ON

0=OFF

1.) 1 Group Output Mode is engaged by flipping the dip-switch 1& 2 to the "OFF"
position, has 1 group output and Output 1~6 is identical.
2.) 2 Group Output Mode is engaged by flipping the dip-switch 1 to the "ON"
position and the dip-switch 2 to the "OFF" position, has 2 group output and has
3 identical outputs distributed over 2 groups, Output1~3 is identical, and Output
4~6 is identical.
3.) 3 Group Output Mode is engaged by flipping the dip-switch 1 to the "OFF"
position and the dip-switch 2 to the "ON" position, has 3 group output and has
2 identical outputs distributed over 3 groups, Output1~2 is identical, Output 3~4
is identical and Output 5~6 is identical.

4.) 6 Group Output Mode is engaged by flipping the dip-switch 1& 2 to the "ON" position, has 6 group output
and Output 1~6 is not perfectly identical.

2.) WHITE Output Mode is engaged by flipping the dip-switch 4 to the "ON" position and the dip-switch 5 to
the "OFF" position, one output with R.G.B. Control is controlled by one channel and the output of R.G.B. Is
identical.

3.) COOL WHITE & WARM WHITE Output Mode is engaged by flipping the dip-switch 4 to the "OFF" position
and the dip-switch 5 to the "ON" position, one output with Cool White & Warm White is controlled by two
channels. The output with Cool White is controlled by Ch 1, and the output of R.B. Is identical; the output
with Warm White is controlled by Ch 2, and the output is G.
4.) RGB Output Mode is engaged by flipping the dip-switch 4 and 5 to the "ON" position, one output with
R.G.B. Control is controlled by three channels separately.