Wilo AlarmControl User Manual

Page 16

Advertising
background image

English

12

Wilo SE 04/2009

3 Transport and interim storage

On receipt of the product, check it for any damage incurred in transit. In the
event of damage in transit, the necessary steps must be taken with the carrier
before the relevant deadlines.
CAUTION! Danger of damage to the switchgear
Danger of damage due to improper handling during transport and storage.

• The switchgear must be protected against moisture and mechanical damage

caused by blows/impact.

• It must not be exposed to temperatures outside the range –20°C to +60°C.

4 Application

WARNING! Danger of personal injury
The alarm switchgear is not explosion-protected.

• Do not install or use the switchgear in potentially explosive areas.

The AlarmControl switchgear emits a warning signal if the water level is too high
in

• Pump shafts
• Lifting units
• Tanks.

A 9V storage battery (included in the scope of supply) is installed so that it can
operate independently of the main power supply.

5 Product data

5.1 Technical data

AlarmControl 1-2

Operating voltage

1 ~ 230 V

Frequency

50/60 Hz

Control voltage

12 V DC (unstabilised)

Standby auxiliary power demand

< 1.5 W

Alarm contact: (AlarmControl only 1)

Potential-free normally open contact,
Max. contact load 1 A (230V AC)

Socket contact: (AlarmControl only 2)

Max. contact load 16 A (250V AC)

Protection class

IP 20

Float switch cable length

3 m (2 x 0.75mm²)

Dimensions: Length

112 mm

Width

68 mm

Height

53 mm (without plug)

Housing

ABS

Temperature range

-20 °C to +60 °C