The cockpit-mounted remote switch assembly is comprised of an ELT status LED and control

switch, and allows an operator to manually turn the ELT on (i.e., activate) for testing and

reset (i.e., deactivate) the ELT. See Figure 3 Remote Switch Front View.

NOTE: The ELT CANNOT be disarmed or disabled from the cockpit. Cockpit operation is

limited to deactivating or manually activating the ELT.

Figure 3 Remote Switch Front View

(3)

The buzzer (i.e., horn) provides an audible alert when the ELT is active. See Figure 4 Buzzer.

Figure 4 Buzzer

(4)

The battery pack for the ME406 Series ELT consists of two “D” size lithium manganese dioxide

cells connected in series. To prevent the cells from being charged, diodes are connected

across each cell and fuses are connected to the output. See Figure 5 Battery Pack Assembly.