1101 module interface and 452-6505 buzzer wiring, Nstructions, Remote switch cell replacement – ACR&Artex ME406 ACE 455-0023 User Manual

Page 21: Helf

Advertising
background image

Artex Products / ACR Electronics, Inc.

570-0023 Rev. G

Page 21 of 33

9.

453-1101 MODULE INTERFACE AND 452-6505 BUZZER WIRING

9.1 Instructions

9.1.1 Follow the appropriate wiring diagram in Section 5, depending if the aircraft is metal or

composite.

Connect RED wire to Horn Power connection
Connect BLACK wire to A/C Ground
Cap & stow BLUE wire

9.1.2 Mount the buzzer according to the instructions highlighted in the ME406 series ELT

manuals.
NOTE: Allow enough slack to prevent tensile load on the wires leading from the module
interface and the buzzer. Depending on the location of the buzzer, additional wires can

be strung between the buzzer and the module interface.

10. REMOTE SWITCH CELL REPLACEMENT

131-0001 CELL WARNING:

DO NOT RECHARGE, SHORT-CIRCUIT, DISASSEMBLE, DEFORM,

HEAT OR PLACE NEAR A DIRECT FLAME

10.1 Cell Shelf Life

10.1.1 The shelf life of the cell is 5 years. The cell is available through ACR Electronics, Inc.

under part number 131-0001.

10.1.2 The Lithium content of the cell is less than 0.15 Gram.