I. airframe ground connections, J. buzzer connections, K. remote switch final installation – ACR&Artex C406-2 HM User Manual

Page 69: 70 j. buzzer connections, Subtask

Advertising
background image

25-62-11

Page 69 of 87

JUN 20/13

ACR ELECTRONICS, INC / ARTEX PRODUCTS

DESCRIPTION, OPERATION, INSTALLATION AND MAINTENANCE MANUAL

C406-2 (453-5000), C406-2HM (453-5001)

SUBTASK 25-62-11-450-008

I.

Airframe Ground Connections

(1)

Connect the ground wires to the airframe in accordance with the aircraft manufacturer’s

written instructions or as described in AC 43.13-1, Chapter 11, § 15, as applicable. See "Figure

21 Remote Switch Harness Wiring Diagram” on page 66.

SUBTASK 25-62-11-450-009

J.

Buzzer Connections

(1)

Connect the power wire to the buzzer positive (+) terminal.

(2)

Connect the ground wire to the buzzer negative (–) terminal.

SUBTASK 25-62-11-450-010

K. Remote Switch Final Installation

(1)

Insert the harness plug into the remote switch receptacle.

(2)

Install the remote switch assembly in accordance with SUBTASK 25-62-11-450-002 on page

62.