Assembling your float free memory capsule – ACR&Artex Float-Free 406 Memory Capsule User Manual

Page 11

Advertising
background image

Y1-03-0199 Rev. E

8

4.2

Assembling your Float Free Memory Capsule


(To remove all components, reverse these directions at step 5).


1.

HRU and warning plate installation







































A) Push the release spring back against the bracket

aligning the holes on the spring with the holes in the
back of the bracket. Take the HRU and place the washer
end of the HRU through the larger top whole and slide
down into the smaller slot.

Turn the HRU to the left side of the bracket. This will
lock the HRU and spring into place. Carefully release
the HRU and make sure it is securely in place.

B)

Insert the metal warning plate behind the spring so
that the bottom of the plate butts up against the HRU.

With the screws provided, secure the warning plate in
place as shown.

HRU Installation

Figure 4

Warning Plate Installation

Figure 5

NOTE: HRU and cutter assembly replacement can be performed more easily by removing the Sea Shelter from the
bulkhead first. This can be done by removing the screws holding the mounting brackets to the bulkhead.

Advertising