Rdr_to_pc_slotstatus – ACS ACR100 SIMFlash (CCID) User Manual

Page 14

Advertising
background image

Document Title Here

Document Title Here

Document Title Here

[email protected]

www.acs.com.hk

Page 14 of 18

ACR100F (CCID) Reference Manual

Version 3.00

[email protected]

www.acs.com.hk

7.1.2.2.

RDR_to_PC_SlotStatus

This message is sent by the smart card reader in response to PC_to_RDR_IccPowerOff,
PC_to_RDR_GetSlotStatus, PC_to_RDR_Abort messages and Class specific ABORT request.

Offset Field

Size Value

Description

0

bMessageTy
pe

1

81h

1

dwLength

4

0000000
0h

Size of extra bytes of this message

5

bSlot

1

Same value as in Bulk-OUT message

6

bSeq

1

Same value as in Bulk-OUT message

7

bStatus

1

Slot status register as defined in CCID section
4.2.1

8

bError

1

Slot error register as defined in CCID section
4.2.1 and this specification section 5.2.8

9

bClockStat
us

1

value =
00h Clock running
01h Clock stopped in state L
02h Clock stopped in state H
03h Clock stopped in an unknown state
All other values are RFU.

Advertising