8

100S

Reference Manual

SETUP

(

S - M

M

LEC =

)

x 1,000,000

S = Standard length
M = Measured length

•

In the DRO mode.

•

Place a standard of known length on the table. Make sure it’s parallel
with the table’s travel.

•

Put the readout in the absolute display mode (

ABS/INCR

key).

•

Using an edge finder or dial indicator, locate one end of the standard.

•

Press the

ZERO

key twice for the axis you are measuring. “0” should

appear on the display.

•

Move the table along the axis until the edge finder or dial indicator
reaches the opposite end of the standard.

•

Write down the length that is shown on the readout display for
that axis.

•

Use the formula below to calculate the LEC for the axis you just
measured. Enter the result in the LEC screen (previous page).

Note: If the measured length is greater than the standard length the

LEC value will be negative.

How to Determine the Linear Error Compensation

Follow this procedure for each axis:

Formula

Example

If the length of the
standard you used is
10” and the measured
length along the X-
axis is 9.995”, then
the LEC for the X-
axis is 500 parts per
million (PPM).

(

10 - 9.995

9.995

LEC =

)

x 1,000,000

LEC =

500 PPM

(rounded to the nearest
whole number)