Sonar alarms, The graph shows in red any water, The graph shows – Garmin GPSMAP 5215 User Manual

Page 98

Advertising
background image

94

GPSMAP

®

4000/5000 Series Owner’s Manual

Sonar

Highlighting the Edge

Note: This feature is available only on the GSD 24 and GSD 26.
You can highlight the strongest signal from the bottom to help define the hardness or softness of the signal.
1. From the Home screen, select Sonar.
2. Select a sonar view.
3. Select Menu > More > Appearance > edge > off.
Setting the Color Scheme

You can set the color scheme for all sonar screens.
1. From the Home screen, select Sonar.
2. Select a sonar view.
3. Select Menu.
4. Select an option:

• For the GSD 22, select Sonar Setup.
• For the GSD 24/26, select More.

5. Select Appearance > Color Scheme.
6. Select an option.
Setting the Color Gain

Note: This feature is available only on the GSD 24 and GSD 26.
You can adjust the color gain to increase or decrease the visual intensity of the sonar screen.
1. From the Home screen, select Sonar.
2. Select a sonar view.
3. Select Menu > More > Appearance > Color Gain.
4. Select an option.

Sonar Alarms

Setting the Shallow Water and Deep Water Alarms

1. From the Home screen, select Configure > Alarms > Sonar.
2. Select Shallow Water > on to set an alarm to sound when the depth is less than the specified value.
3. Enter the depth that triggers the shallow water alarm:

• For the GPSMAP 4000 series, use the Rocker or Numeric Keypad.
• For the GPSMAP 5000 series, use the on-screen keyboard.

4. Select Done.
5. Select Deep Water > on to set an alarm to sound when the depth is greater than the specified value.
6. Enter the depth that triggers the deep water alarm:

• For the GPSMAP 4000 series, use the Rocker or Numeric Keypad.
• For the GPSMAP 5000 series, use the on-screen keyboard.

7. Select Done.
Setting the Water Temperature Alarm

You can set an alarm to sound when the transducer reports a temperature that is 2°F (1.1°C) above or below

the specified temperature.
1. From the Home screen, select Configure > Alarms > Sonar > Water temp > on.
2. Enter a water temperature:

• For the GPSMAP 4000 series, use the Rocker or the Numeric Keypad.
• For the GPSMAP 5000 series, use the on-screen keyboard.

3. Select Done.