Removing the dimm from a perc x/i controller – Dell PowerEdge RAID Controller 6E User Manual

Page 12

Advertising
background image

10

Removing and Installing the Battery and Battery Cable on PERC Controllers

Removing the DIMM from a PERC

x/i Controller

This section describes the procedure to remove the memory module from
a PERC x/i Adapter or PERC x/i Integrated controller installed in a system.

CAUTION:

Only trained service technicians are authorized to remove the system

cover and access any of the components inside the system. Before performing any
procedure, see your Product Information Guide for complete information about
safety precautions, working inside the computer, and protecting against
electrostatic discharge.

NOTICE:

Depending on the generation of your PERC card, the DIMM memory

module may not be removable. PERC 5/i cards include a removable DIMM module.
PERC 6/i cards have an integrated DIMM module which cannot be removed. Do not
attempt the following procedure on a PERC 6/i adapter or integrated controller card.

1 Perform a controlled shutdown of the system in which the PERC x/i

controller is installed and remove the PERC x/i controller from the system.
See the Dell PowerEdge Expandable RAID Controller x/i and x/E User’s
Guide for more information.

CAUTION:

Running a system without the system cover installed may cause

damage due to improper cooling.

2 Remove the memory module by pressing down on the tabs at each edge

of the memory module connector and lifting the memory module off the
controller.

NOTE:

Do not exert excessive pressure on the connector on the memory

module while removing the memory module.

NOTE:

The location of the PERC x/i Integrated controller varies from system

to system. See the Hardware Owner’s Manual included with the system for
specific information on where the PERC x/i Integrated controller is located.

Advertising