Dell PowerEdge C6145 User Manual

Page 15

Advertising
background image

Getting Started With Your System | 15

Environmental

NOTE: For additional information about environmental measurements for specific system
configurations, see www.dell.com/environmental_datasheets.

Temperature

Operating

10° to 35°C (50° to 95°F) with a
maximum temperature gradation of
10°C per hour

NOTE: For altitudes above 2950 feet, the maximum
operating temperature is derated 1°F/550 ft.

Storage

–40° to 65°C (–40° to 149°F) with a
maximum temperature gradation of
20°C per hour

Relative humidity

Operating

20% to 80% (noncondensing) with a
maximum humidity gradation of 10%
per hour

Storage

5% to 95% (noncondensing)

Maximum vibration

Operating

0.26 Grms at 5–350 Hz

Storage

1.88 Grms at 10–500 Hz for 15 min

Maximum shock

Operating One

shock

pulse

in the positive z axis

(one pulse on each side of the system)
of 31 G for 2.6 ms in the operational
orientation

Storage

Six consecutively executed shock
pulses in the positive and negative x, y,
and z axes (one pulse on each side of
the system) of 71 G for up to 2 ms;
Six consecutively executed shock
pulses in the positive and negative x, y,
and z axes (one pulse on each side of
the system) of 22 G faired square wave
pulse with velocity change at 200
inches/second (508 centimeters/second)

Advertising