Dell PowerEdge R715 User Manual

Page 14

Advertising
background image

12

Getting Started With Your System

Relative humidity

Operating

20% to 80% (noncondensing) with a maximum
humidity gradation of 10% per hour

Storage

5% to 95% (noncondensing)

Maximum vibration

Operating

0.26 G at 5–350 Hz for 15 min

Storage

1.54 G at 10–250 Hz for 15 min

Maximum shock

Operating

One shock pulse in the positive z axis (one pulse on
each side of the system) of 31 G for 2.6 ms in the
operational orientation

Storage

Six consecutively executed shock pulses in the
positive and negative x, y, and z axes (one pulse on
each side of the system) of 71 G for up to 2 ms

Altitude

Operating

–16 to 3,048 m (–50 to 10,000 ft)

NOTE:

For altitudes above 2950 feet, the maximum

operating temperature is derated 1ºF/550 ft.

Storage

–16 to 10,600 m (–50 to 35,000 ft)

Airborne Contaminant Level

Class

G2 or lower as defined by ISA-S71.04-1985

Environmental (continued)