12
Getting Started With Your System
Environmental
NOTE:
For additional information about environmental measurements for specific
system configurations, see
www.dell.com/environmental_datasheets.
Temperature
Operating
10° to 35°C (50° to 95°F) with a maximum 
temperature gradation of 10°C per hour
NOTE:
For altitudes above 2950 feet,
the maximum operating temperature is 
derated 1ºF/550 ft.
Storage
–40° to 65°C (–40° to 149°F) with 
a maximum temperature gradation of 
20°C per hour
Relative humidity
Operating
20% to 80% (noncondensing) with 
a maximum humidity gradation of 
10% per hour
Storage
5% to 95% (noncondensing)
Maximum vibration
Operating
0.26 G at 5–350 Hz for 15 min
Storage
0.5 G at 3–200 Hz for 15 min
Maximum shock
Operating
One shock pulse in the positive z axis 
(one pulse on each side of the system) of 
31 G for 2.6 ms in the operational orientation
Storage
Six consecutively executed shock pulses 
in the positive and negative x, y, and z axes 
(one pulse on each side of the system) 
of 71 G for up to 2 ms