Getting Started With Your System | 14

Power
NOTE:
The system doesn’t support a mixed installation of 1200 W and 1400 W power supplies.

NOTE: Both of these two PSUs are swappable, and they can support hot swap in any condition if

system has power throttling feature.

AC power supply (per power supply)
Wattage

1200 W

Voltage

100-240 VAC, 50/60 Hz, maximum input

current: 12.0-8.0 Amps

NOTE: For 1200 W power supply, output 1200 W is for

high line (input 200-240 VAC), output 1023 W is for low

line (input 100-120 VAC).

Heat dissipation

4016.251 BTU/hr maximum

Maximum inrush current

Initial In-rush Current cannot exceed 55

Amps (peak). Secondary In-rush Current

cannot exceed 35 Amps (peak).

Wattage

1400 W

Voltage

200-240 VAC, 50-60 Hz, maximum input

current: 9.0 Amps

Heat dissipation

6024.376 BTU/hr maximum.

Maximum in-rush current

Initial In-rush Current cannot exceed 55

Amps (peak). Secondary In-rush Current

cannot exceed 25 Amps (peak).

Battery (per system board)
System battery

CR 2032 3.0-V lithium ion coin cell

Physical

Height

8.68 cm (3.42 in)

Width

44.8 cm (17.6 in)

Depth

79.0 cm (31.1 in)

Weight (maximum

configuration)

41 kg (90.38 lb) (with 12*3.5” HDD)

Weight (empty)

15.3 kg (33.73 lb) (with 2.5” HDD bay)
16.2 kg (35.71 lb) (with 3.5” HDD bay)