Dell PowerVault DP600 User Manual

Page 17

Advertising
background image

Getting Started With Your System

15

Tower (without bezel)

Height

47.89 cm (18.85 in) with feet, no casters

Width

22.66 cm (8.92 in)

Depth

66.13 cm (26.04 in) does not include control panel or
bezel; control panel adds an additional 1.3 cm (.51 in)

Weight (maximum
configuration)

49.9 kg (110 lb)

Environmental

NOTE:

For additional information about environmental measurements for specific

system configurations, contact your technical support provider.

Temperature

Operating

10° to 35°C (50° to 95°F)

Storage

–40° to 65°C (–40° to 149°F)

Relative humidity

Operating

20% to 80% (noncondensing) with a maximum
humidity gradation of 10% per hour

Storage

5% to 95% (noncondensing)

Maximum vibration

Operating

0.26 G from 5–350Hz for 2 min in the Z axis

Storage

1.54 G from 10–250 Hz for 15 min in all
orientations

Maximum shock

Operating

One shock pulse in the positive z axis (one pulse
on each side of the system) of 41 G for up to 2 ms

Storage

Six consecutively executed shock pulses in the
positive and negative x, y, and z axes (one pulse
on each side of the system) of 71 G for up to 2 ms

Altitude

Operating

–16 to 3048 m (–50 to 10,000 ft)

Storage

–16 to 10,600 m (–50 to 35,000 ft)

Physical (continued)