Dell 7700HD Projector User Manual

Page 7

Advertising
background image

tion

pdmAudio pdmAudioVolume

.1.3.6.1.4.1.2699.2.4.1.16.2.0 Integer

R/W

pdmAudio

pdmAudioMute

.1.3.6.1.4.1.2699.2.4.1.16.3.0

Integer R/W

pdmAudio

pdmAudioTreble .1.3.6.1.4.1.2699.2.4.1.16.4.0

Integer R

DEFVAL { 0 }

pdmAudio

pdmAudioBass

.1.3.6.1.4.1.2699.2.4.1.16.5.0

Integer R

DEFVAL { 0 }

pdmAudio

pdmAudioBalance .1.3.6.1.4.1.2699.2.4.1.16.6.0

Integer R

DEFVAL { 0 }

pdmAlert

pdmAlertIndex

1.3.6.1.4.1.2699.2.4.1.18.1.1.1.1

Integer not-accessible 1

pdmAlert

pdmAlertGroupTy
pe

1.3.6.1.4.1.2699.2.4.1.18.1.1.2.1 String

R

See

Note

1

pdmAlert

pdmAlertGroupId 1.3.6.1.4.1.2699.2.4.1.18.1.1.3.1

String

R

See Note 1

pdmAlert

pdmAlertCode

1.3.6.1.4.1.2699.2.4.1.18.1.1.4.1

String

R

DEFVAL { "" }

pdmAlert

pdmAlertDescripti
on

1.3.6.1.4.1.2699.2.4.1.18.1.1.5.1

String

R

Alert's condition has lamp Fail,
Lamp hours running out,
Projector Overheating, Lamp
Overheating and Fan Error.

pdmAlert

pdmAlertSeverityL
evel

1.3.6.1.4.1.2699.2.4.1.18.1.1.6.1 Integer

R

See

Note

1

pdmAlert

pdmAlertTraining
Level

1.3.6.1.4.1.2699.2.4.1.18.1.1.7.1

Integer R

DEFVAL { 2 }

pdmAlert

pdmAlertDateTim
e

1.3.6.1.4.1.2699.2.4.1.18.1.1.8.1 String

R

DEFVAL
{ "1980-01-01T00:00:00" }

pdmAlert

pdmAlertPowerOn
Count

1.3.6.1.4.1.2699.2.4.1.18.1.1.9.1

String

R

DEFVAL { "" }

pdmAlert

pdmAlertSysUpti
me

1.3.6.1.4.1.2699.2.4.1.18.1.1.10.1

String

R

DEFVAL { "" }

pdmAlert

pdmAlertCriticalA
lertsCount

1.3.6.1.4.1.2699.2.4.1.18.2.0

Integer R

pdmAlert

pdmAlertAllAlerts
Count

1.3.6.1.4.1.2699.2.4.1.18.3.0 Integer

R

Note 1:
a) If there is no any current alert, all of OID in alert table will respond default value.
pdmAlertGroupType =” “
pdmAlertGroupID = 0
pdmAlertSeverity = other (1)
The reset Object will respond default.

b) If there is FAN alert happen, the tables is shown below.
pdmAlertGroupType =” Fan”
pdmAlertGroupID = “Fan Error”
pdmAlertSeverity = Critical (3)
The rest Object will respond default.

c) If there is Lamp fail alert happen, the tables is shown below.
pdmAlertGroupType = “Lamp”
pdmAlertGroupID= Lamp Fail
pdmAlertSeverity = Critical (3)
The rest Object will respond default.

d) If there is Lamp hours running out alert happen, the tables is shown below.
pdmAlertGroupType = “Lamp”
pdmAlertGroupID= Lamp hours running out
pdmAlertSeverity = warning (4)
The rest Object will respond default.

e) If there is Projector Over-heating alert, the tables is shown below.
pdmAlertGroupType = “ThermalSensor”
pdmAlertGroupID= “Projector Overheating”
pdmAlertSeverity = warning (4)
The rest Object will respond default.

f) If there is Lamp Over-heating alert, the tables is shown below.
pdmAlertGroupType = “ThermalSwitch”
pdmAlertGroupID= “Lamp Overheating”
pdmAlertSeverity = Critical (3)
The rest Object will respond default.
Information in this document is subject to change without notice.

© 2012 Dell Inc. All rights reserved.
Reproduction in any manner whatsoever without the written permission of Dell Inc. is strictly forbidden.
Trademarks used in this text: Dell and the DELL logo are trademarks of Dell Inc.
Other trademarks and trade names may be used in this document to refer to either the entities claiming the marks and names or
their products. Dell Inc. disclaims any proprietary interest in trademarks and trade names other than its own.

Advertising