Making Load Connections (continued)
Figure 2.7-2 Bus Bar Shield
To make load connections to a typical 7.5V, 140A power supply:
1. Install connectors such as the Thomas and Betts wire connector #54158 to load wiring.
2. Fasten connectors to bus bars with 5/16" x 5/8" (M8 x 16 mm) screws and 5/16" (M8) flat washers,
lock washers, and hex nuts as shown in Figure 2.7-3.
Note:
Bus bar hole sizes for the low voltage models are: 1 of 0.332" (8.17 mm) D; and 2 of 0.197" (5.0 mm) D.
Figure 2.7-3 Typical Load Connection Hardware
(Low voltage model shown.)
Wire Connector
(2 places)
Screw (2 places)
Hex Nut (2 places)
Lock Washer (2 places)
Flat Washer (2 places)
Shield
Flat Washer (3 places)
Assembled View
Lock Washer (3 places)
1/4" Screw (2 places)
3/8" screw (1