8.3.1 Overview
XTAccess is able, with the scan folder, to transcode one High Res file to Low Res and
reference it into Xedio DB.
8.3.2 Workflow
1. A file is dropped in the ScanFolder (D:\myScanFolder\myFile.evs.mxf)
2. The transcoded file and its companion EVS_Metadata file is generated in
D:\CleanEdit\Low\
3. If the job succeeds, the source file (C:\myScanFolder\myFile.evs.mxf) is moved to
D:\CleanEdit\High\
4. The two files are referenced into Xedio
8.3.3 Remarks
•
To use the Xedio referencing: you need to install the
CEXTAccessIntegration_vxx.xx.xx.exe and configure the CleanEdit ODBC Through
the