4 lever engage mode, 5 second lever range, Ever – EVS MulticamLSM Version 10.01 - October 2009 Configuration Manual User Manual
Page 70: Ngage, Econd, Ange

EVS Multicam Version 10.01 – Configuration Manual
EVS Broadcast Equipment SA – October 2009
Issue 10.01.I
63
OR
•
the speed range defined by the lever is limited to the value specified by this
parameter (VarMax mode ON).
3.13.4 L
EVER
E
NGAGE
M
ODE
Possible values: Direct (default) / Current speed
The speed variation depends on the position of the T-Bar lever.
•
Direct mode: the lever will engage directly when moved, resulting in a speed
jump to the desired speed determined by the lever arm position.
•
Current speed mode: the lever will only engage when it reaches the current
playback speed, whereas a move of the lever arm in the opposite direction of
the current speed will result in a direct speed change.
3.13.5 S
ECOND
L
EVER
R
ANGE
The lever can be used in normal mode to play back clips at slow motion speed
from 0 to 100%. A secondary range is available to playback material at the
following speed ranges:
-100% Î ±100% (default)
0 О 200%
-200% О±200%
0 О 400%
-400% О ±400%
To gain access to the secondary speed from the remote controller, press SHIFT +
LEVER/TAKE.
The second lever range is also available when editing the speed of playlist clips.