Why use the ge marquette 12sl ecg analysis program, A pioneer in technology innovation – GE Healthcare Marquette 12SL ECG User Manual
Page 3
 
• Analysis of Artificially–Paced Rhythms – When an
artificial pacemaker stimulus is detected, the Marquette 
12SL program will identify the underlying rhythm. And in 
conjunction with the CAM HD, GE’s high-definition ECG 
acquisition module, the 12SL program is able to identify 
a biventricular paced rhythm.
• Acute Coronary Syndrome Tool – The 12SL ACS tool
†††
provides higher-sensitivity analysis for ST-Elevated MI 
or Acute Ischemia for patients suspected of having an 
acute cardiac event. The tool heavily weighs the finding 
of ST elevation with reciprocal ST depression. This is a very 
important and highly-specific indicator of STEMI and ACS that 
has been found to “identify patients who stand to benefit 
most from early interventional strategies.” 
4
A study evaluated
on over 1,900 clinically correlated ECGs from patients 
suspected of having ACS showed that the ACS tool:
– Improved the sensitivity of emergency physicians’
interpretation of acute myocardial infarction by 50% 
and cardiologists’ interpretations by 26%, with no loss 
of specificity 
5
– Improved the sensitivity of emergency physicians’
acute ischemic syndrome interpretation by 53% while 
maintaining a specificity of 91% 
5
Why use the GE Marquette 12SL 
ECG analysis program? 
• Meets all applicable standards for computerized
resting ECG analysis
6
, including 15 lead analysis
for pediatric patients.
7
• Automated decision support that has clinical “gold
standard” verified accuracy and is tested against 
a large database of ECGs with multiple diseases 
and varying degrees of abnormality.
• Suggests additional findings not initially detected
and encourages careful, targeted review of the 
ECG tracing.
• Computerized analysis including atrial arrhythmias,
pace detection, and QT measurement.
• Minimizes the time spent over-reading ECGs.
8
• Provides measurements of heart rate, axis, intervals
and durations.
• Pediatric age-driven interpretation criteria.
• Adult gender and age driven interpretation criteria
for acute MI. Utilized in pre-hospital defibrillators to 
identify clinically-significant changes and expedite 
patient care in time-critical environments.
• Assists with ECG interpretation training assistance.
A pioneer in technology innovation
GE has pioneered the technology and expertise by making 
the Marquette 12SL program available throughout a patient’s 
entire cardiac experience, from pre-hospital through follow-up. 
The Marquette 12SL program operates on a variety of platforms 
and currently exists in these areas:
• Pre-hospital environment
• Emergency department
• General hospital departments
• CCU/ICU
• Exercise testing labs
• Clinics
• Physician offices
Advanced Interpretation of Paced Rhythms
Marquette 12SL provides analysis for detecting bi-ventricular 
pacemakers, identifying the underlying rhythm, in addition to 
the chamber(s) being paced