Acculevel, Optional: setting caster to .1, Setting digital caster only – Longacre 78290 Digital Caster_Camber Gauge with AccuLevel (version 2) User Manual

Page 2: Digital caster only

Advertising
background image

OPTIONAL: Setting Caster To .1

O

(1/10

O

)

1) To set CASTER more precisely using the

AccuLevel™

digital readout (instead of the vial)

first turn the wheels 15

O

(this is different than when using vial type gauges)

to the right when

setting the RF or 15

O

left when setting LF. Rotate the gauge until it is level.

2) Turn on the

AccuLevel™

and push ZERO to zero degrees at that point (shows

00.0

00.0

00.0

00.0

00.0

O

).

3) Turn wheels back to center and continue to 15

O

in the other direction (a total of 30

O

). Again this is

different than when using vial type gauges.

The 15

O

must be done accuretely. An error of even 1 or

2

O

turning will give a noticeable caster error. Consider turnplates for the best accuracy.

4) Rotate gauge to level. Read the digital display and DOUBLE THE NUMBER FOR (TOTAL)
CASTER, accurate to .1

O

. For example display reads 1.8

O

x 2 = 3.6

O

caster.

Using 15

O

rather than 20

O

wheel turning is sometimes better on race cars. On some front ends

it can be difficult to turn the wheels a full 20

O

, which will cause an error in the caster reading.

Gauges are calibrated to use either 15

O

or 20

O

turning and cannot be interchanged.

AccuLevel™

can be removed and used

for other measurements. Simply slide it out
(it’s held in place with magnets).

Turn on: Push ON/OFF.

AccuLevel™

is

ready to use.

ABS

ABS

ABS

ABS

ABS

will appear on the display if

the unit is in Absolute Angle Measurement Mode.
If it does not display

ABS

ABS

ABS

ABS

ABS

push ZERO.

Zero: The ZERO button is ONLY used to
compare one angle to another. Place

AccuLevel™

on an angled surface and push ZERO. The display will go to

00.0

00.0

00.0

00.0

00.0

and

ABS

ABS

ABS

ABS

ABS

will disappear. Move to

a different surface to compare angles .FOR NORMAL USE

ABS

ABS

ABS

ABS

ABS

MUST BE ON DISPLAY.

Push ZERO again to go back to Absolute Angle Measurement (

ABS

ABS

ABS

ABS

ABS

)Mode.

To hold reading: Push “HOLD”. The display will show HOLD and flash . When HOLD stops
flashing (approx. 6 sec.) the reading is held on the display.

AccuLevel™

must be head very

steady during this 6 seconds. Push “HOLD” again to go back to absolute reading.

To CALIBRATE: Place

AccuLevel™

on a reasonably level table top (does not need to be

perfectly level). Push ON/OFF and hold for 6 seconds and release. Push ON/OFF again and

- 1 -

- 1 -

- 1 -

- 1 -

- 1 -

appears on the display. Push ZERO.

- 1 -

- 1 -

- 1 -

- 1 -

- 1 -

will begin to flash and in a few seconds

- 2 -

- 2 -

- 2 -

- 2 -

- 2 -

will appear.

Turn unit around 180

O

in the same spot and push ZERO again.

- 2 -

- 2 -

- 2 -

- 2 -

- 2 -

will begin to flash and in a few

seconds normal readings will reappear. Calibration is now complete. This takes less than 30 seconds.

AccuLevel

SETTING DIGITAL CASTER ONLY

11/06

15

O

15

O

DIGITAL CASTER ONLY

Turn wheels 15

O

each way when

setting Digital caster

(20

O

using

vial)

00.0

00.0

00.0

00.0

00.0

ABS

HOLD

Advertising