CD Indicators

3.11 Custom Unit (Cont.)

Procedure (Cont.)

• Press Enter button, SAVED is momementary dis-

played followed by LSD. There are 6 LSD (least

significant settings you can choose from (see table).

3.12 Menu Lock-Out Protection

For type approved Indicators, consult local Weights and
Measures officials to determine sealing method require-
ments.

After the Indicator has been set up properly, calibrated
and the menus are locked out (refer to paragraph 4.1
Calibration), proceed to seal the indicator.

For a lead and wire seal, place the sealing plate into
position and run sealing wire through holes in plastic
retainers. Run wire through lead seal and crimp closed as
shown. Alternate LFT paper seal should be positioned
half on the sealing plate and half on the plastic cover.

Indicator Connection Compartment Open

Indicator Connection Compartment Sealed

Access to the

various menus can be disabled by inserting

the Lock Switch jumper located on the bottom of the
Indicator underneath the Terminal Block. See figure for
location. The Lock Switch jumper when removed, locks
out all menus which have had LOCK turned ON. The
default setting for the Lock Switch jumper is OFF (jumper
on).

Type Approved/Legal for Trade
Indicator Sealing

All CD-31 and CD-33 Indicators may be sealed for type
approved/legal for trade applications. A sealing kit is
provided with the Indicator. The kit includes a lead seal
with wire, screws and cover as shown.

• Press Enter button, LSD 1 is displayed.

• Press

or

button and select LSD value.

• Press Enter button, LOCK is displayed.

• Press Enter button, LOCK OFF is displayed.

• Press

or

button and select ON or OFF.

• Press Enter button, EXIT is displayed.

• Press Enter button, Indicator returns to weigh mode.

LSD’s

LSD .5

Adds one decimal place
display counts by 5’s.

LSD 1

Display counts by 1’s.

LSD 2

Display counts by 2’s.

LSD 5

Display counts by 5’s.

LSD 10

Display counts by 10’s.

LSD 100

Display counts by 100’s.