Velleman VM122 User Manual

Page 6

Advertising
background image

6

output & address selection

ADDRESS

SELECTION

D18 D19

1

Cut Cut

2

Cut

Do not Cut

3

Do not cut

Cut

OUTPUT SELECTION :

All outputs are toggle outputs by default.

To obtain a momentary output (pushbutton functionality), cut the
corresponding diode (D1...15).

For example: if you want to make output 5 a momentary instead of a
toggle output, cut or remove diode D5.

ADDRESS SELECTION :

Different possibilities in conjunction with diode setup:

The address selection allows you to operate up to 3 receivers in the same room without interference. Each receiver shall
have its own address setting.

HINT: 3 receivers in the same room gives you 45 outputs thanks to address setting.


DEFAULT MODE : 3








ATTENTION: the receivers can only be operated by a transmitter allowing address setting. For the setting of the
transmitter, we refer to the manual of VM121.