Velleman VMB4RYLD User Manual

Page 15

Advertising
background image

VMB4RYLD 4-channel relay module user manual - version 1

15

24

Restartable interval timer

Pressing the pushbutton will switch on the interval timer for a
preset time. The output is thus repeatedly open and closed. The
switch-on and switch-off delays can be set.
Pressing the pushbutton while the interval timer is running will
restart the interval timer.

25

Non restartable interval timer

Pressing the pushbutton will switch on the interval timer for a
preset time. The output is thus repeatedly open and closed. The
switch-on and switch-off delays can be set.

26

Forced off at closed switch

The relay cannot be switched on as long as the switch is closed.
A light sensor will keep the driveway lighting switched off during
daylight.

27

Forced off at opened switch

The relay cannot be switched on as long as the switch is open.

28

Forced off at pushbutton press

Pressing the pushbutton will disable the switching-on of the relay
for a preset time.
The use of a control panel with weekly program allows you to
disable the output control of an output for a preset time.

29

Toggle forced off at
pushbutton press

Pressing the pushbutton will disable the switching-on of the relay
for a preset time.
Repressing that same pushbutton will cancel the forced-off mode.

30

Cancel forced off at
pushbutton press

Pressing the pushbutton will cancel the forced-off mode.
Remark:
The forced-off status can still be determined by the function forced
off at opened or closed switch.

31

Forced on at closed switch

The relay is switched on as long as the switch is closed. All other
commands are ignored.
Remark:
The forced-off function overrules the forced-on function.

32

Forced on at open switch

The relay is switched on as long as the switch is open. All other
commands are ignored.
Remark:
The forced-off function overrules the forced-on function.

33

Forced on at pushbutton press

Pressing the pushbutton will switch on the relay. All other
commands are ignored for a preset time.
Remark:
The forced-off function overrules the forced-on function.

34

Toggle forced-on at
pushbutton press

Pressing the pushbutton will switch on the relay. All other
commands are ignored for a preset time. Repressing that same
pushbutton will cancel the forced-on mode.
Remark:
The forced-off function overrules the forced-on function.

35

Cancel forced-on at
pushbutton press

Pressing the pushbutton will cancel the forced-on mode.
Remark:
The forced-on status can still be determined by the function forced
off at opened or closed switch.

36

Inhibit at closed switch

The relay is switched off as long as the switch is closed. The
functions will still be active internally. The internal status will be
transferred to the relay at the opening of the switch.

37

Inhibit at open switch

The relay is switched off as long as the switch is open. The
functions will still be active internally. The internal status will be
transferred to the relay at the closing of the switch.

38

Inhibit at pushbutton press

Pressing the pushbutton will switch off the relay for a preset time.
The functions will still be active internally.

39

Toggle inhibit at pushbutton
press

Pressing the pushbutton will switch off the relay for a preset time.
The functions will still be active internally. Repressing that same
pushbutton will cancel the inhibition mode.