Mains voltage connection diagram – Velleman VMB4RYLD User Manual

Page 9

Advertising
background image

VMB4RYLD 4-channel relay module user manual - version 1

9

USE


Connecting a 230V mains voltage to the input allows you to switch 4 mains voltage consumers like lighting, a
pump, an electric heater, electric valves, etc.

Connecting a 12V low voltage to the input allows you to switch 4 low-voltage consumers like low-voltage lighting,
LED strips, low-voltage LED spots, etc.

The module is integrated into the Velbus system and controlled through the VMB4PD control panel or by means
of pushbuttons connected to a VMB8PB pushbutton interface, VMB6IN or any other relay module.
To interconnect the Velbus modules it is recommended to use a twisted-pair cable (EIB 2x2x0.8mm², UTP
4x2x0.51mm² - CAT5 or equivalent).
Make sure to use a heavy-gauge wire (0.5mm

2

or more) in case of a multiple module connection (>10 modules) or

with log connections (>50m).
Connect the bus to the module (mind the polarity).

Mains Voltage Connection Diagram


A single-pole load (e.g. lighting) can be connected directly to the output.

Maximum total current consumption: 16A