SET-UP

Transmitter

(1) Relay action output set-up

Each relay can be individually configured to behave as a toggle (ON/OFF) or as a pulse contact.

Hold ‘shift’ until the LED on the remote lights to enter the ‘set-up’-mode then press ‘1’ to enter output setup mode :

Press a button (1..8) to change the function of the corresponding output:

LED flashes once: pulse mode,

LED flashes twice: toggle mode.

Next, press ‘shift’ several times until the LED turns off to leave setup mode (*).

(2) Card address selection set-up (see also page 10)

In order to operate multiple units in close proximity without interference, each unit must have a unique address.
8 addresses are available, default address is 1.

>> > First make sure the card is powered see page 5 !

How to check the current address:

Hold ‘shift’ until the LED lights to enter the ‘set-up’-mode.

Press ‘2’ to display the current address, the relay LED's LD5..LD8 indicate current address (see table).

Next, press ‘shift’ several times until the LED turns off to leave setup mode (*).

How to change the address:

Hold ‘shift’ until the LED lights to enter the ‘set-up’-mode.

Press ‘3’ to allow address change, pressing a button (1..8) will change the address of the remote and the relay card

(see table).

Next, press ‘shift’ several times until the LED turns off to leave setup mode (*).

If more than one transmitter is used, please repeat point 2 using the other transmitter

Attention: All active cards will respond to this command. Remove power from cards which do not need to change their address.

(*) NOTE: If no button is pushed for about 15s, the unit will leave ‘setup’-mode automatically.