Welcome to the world of pc, Welcome – Velleman PCSGU250 User Manual

Page 4

Advertising
background image

4

Welcome to the world of Pc

Welcome to the world of Pc

Welcome to the world of Pc

Welcome to the world of Pc----Lab2000

Lab2000

Lab2000

Lab2000

LT

LT

LT

LT

For the PCSGU250 unit, a complete USB-powered lab-in-a-box!
Feature-packed PCLab2000LT software for two channel oscilloscope, spectrum
analyzer, recorder, function generator and Bode plotter. Integrated signal wave
editor and automated sequence generator, using file or external input.

T

TT

The hardware is not necessary to evaluate the software in Demo mode

.

Welcome

Welcome

Welcome

Welcome

Function generator

Function generator

Function generator

Function generator

frequency range: sine from 0.005Hz to 1MHz

square and triangle from 0.005Hz to 500kHz

extended waveform library

amplitude range: 100mVpp to 10Vpp @ 1KHz//
600ohm load / output impedance: 50ohm


Oscilloscope

Oscilloscope

Oscilloscope

Oscilloscope

bandwidth: two channels DC to 12 MHz ±3dB

input impedance: 1 Mohm / 30pF

maximum input voltage: 30V (AC + DC)

time base: 0.1µs to 500ms per division

input range: 10mV to 3V/division

readouts: True RMS, dBV, dBm, p to p, Duty
cycle, Frequency…

record length: 4K samples / channel

sampling frequency: 250Hz to 25MHz

sample history and digital grab function


Bode plotter

Bode plotter

Bode plotter

Bode plotter

Automated sync between oscilloscope and gen-
erator

Frequency range: 1kHz , 10kHz, 100kHz, 1MHz

Frequency start: 10Hz, 100Hz, 1kHz, 10kHz

General information

General information

General information

General information

markers for amplitude/voltage and fre-
quency/time

input coupling: DC, AC and GND

8 bit resolution

storage of display and data

supply from USB port (500mA)****

dimensions: 205 x 55 X 175 / 8,2 x 2,2 x 7"


Spectrum analyser:

Spectrum analyser:

Spectrum analyser:

Spectrum analyser:

frequency range: 0 .. 120Hz to 12MHz

linear or logarithmic timescale

operating principle: FFT (Fast Fourier Trans-
form)

FFT resolution: 2048 lines

FFT input channel: CH1 or CH2

zoom function


Transient recorder:

Transient recorder:

Transient recorder:

Transient recorder:

timescale: 20ms/Div to 2000s/Div

max record time: 9.4hour/screen

automatic storage of data

automatic recording for more than 1 year

max. number of samples: 100/s

min. number of samples: 1 sample/20s

* NOTE: it is NOT recommended to use an USB

* NOTE: it is NOT recommended to use an USB

* NOTE: it is NOT recommended to use an USB

* NOTE: it is NOT recommended to use an USB ---- HUB device, this can cause the software to stop working.

HUB device, this can cause the software to stop working.

HUB device, this can cause the software to stop working.

HUB device, this can cause the software to stop working.

SPECIFICATIONS ARE SUBJECT TO MODIFICATIONS - DLL available for own development - www.velleman.eu