Veris Verabar V110 Spec Sheet User Manual

Verabar, Regular models

Advertising
background image

The Most Accurate and Reliable Technology
for Measuring Gas, Liquid and Steam…

Developed from aerospace technology,
the Verabar

®

averaging pitot flow

sensor provides unsurpassed
accuracy and reliability.
With its solid, one-piece
construction and bullet
shape, the Verabar
makes flow
measurement
leak proof
and precise.

The unique
sensor shape
reduces drag and flow induced vibration. The location
of the low-pressure ports eliminates the potential for
clogging and improves signal stability.

Regular Models

V100 & V110 Compression Fitting

Differential Pressure Flow Sensors

Verabar

®

Model

V110

Model
V100

V100 Single Support
V110 Opposite Support

Pipe Connection

Threaded (NPT)

Mounting Type

Tube fitting

Features and

• Most cost effective model

Benefits

• Installed in less than one hour
Low and medium pressures

• Pipes (steel, PVC, FRP, copper)
• Air (compressed, combustion)
• Natural gas

Applications

• Stack/flue gas
• Water (raw, cooling, feedwater)
• Low pressure steam
• Non-hazardous fluids

Special Designs —

• Custom mounting, lengths, materials,

Consult Factory

instrument connections, etc.

• Short straight run

Temperature

Pressure

Limits

(ANSI Class)*

300#

740 psig @ 100°F

(51.0 Bars @ 38°C)

410 psig @ 800°F

(28.3 Bars @ 426°C)

600#

1440 psig @ 100°F

(99.3 Bars @ 38°C)

825 psig @ 800°F

(56.9 Bars @ 426°C)

* DIN and JIS flanges available. Consult factory.

Model Specifications

V100 and V110

Sensor Code

05

10

Sensor Diameter

7/16” (11mm)

7/8” (22mm)

Accuracy

±1% of flow rate; ±0.5% if calibrated

ANSI Class*

600#

300#

Pipe Size

2”- 6”

6”- 48”

(50mm -150mm)

(150mm -1200mm)

Instrument Connection

1/2” NPT

1/2” NPT or Direct Mount

Components Furnished

Weld coupling, tube fitting;

V110 includes additional weld coupling and plug

Weld Coupling Size

3/4” NPT

1” NPT

Advertising