Unlock operations – V-Tech VT596F_KP Manual User Manual

Page 11

Advertising
background image

6. Unlock Operations

When•the•registered•user•code•has•been•input•using•the•keypad•(1~12•digits),•the•LED•indicator•(red)•lights•
up,•the•buzzer•sounds,and•the•electric•door•strike•is•unlocked.(note•that•you•should•press•"#"•button(if•"#"•
button•is•set•to•confirm•button)•after•input•the•unlock•code)

•• The•time•interval•during•which•the•button•must•be•pressed•is•approximately•10•seconds.•If•

the•time•interval•exceeds•approximately•10•seconds,•the•input•value•will•be•cleared.

•• If•you•make•a•mistake•when•inputting•the•user•code,press•the"•cancel"•button•and•input•the•

user•code•again.

•• If•10•times•incorrect•access•codes•are•continuously•attempted,•the•release•function•is•

forbidden•and•the•input•operation•is•disabled•for•60•seconds•.•During•this•time,the•buzzer•will•

continuously•sound•about•8•times.

•• You•can•activate•the•electric•door•strike•by•pressing•the•request•to•exit•button•connected•to•

the•unit.•(The•unlock•function•will•work•when•the•request•to•exit•button•is•pushed,•even•while•

the•keypad•operating•is•forbidden.)

Example:•

(red)

ON

(blue)

OFF

Beep+

Red LED lights up

(during relay1 operation)

Unlock code=2011

Unlocking of user code

1.•During•calling,pressing•"cancel"•button•can•cancel•the•calling
2.•If•input•the•incorrect•access•code,the•buzzer•will•sound•of•beep,beep,beep

-10-

Advertising