Electric Lock Connection

Door Lock Controlled with Internal Power

•••••Note:

1.• Electronic•lock•of•Power-on-to-unlock•type•should•be•used.
2.• The•door•lock•is•limited•to•12V,•and•holding•current•must•be•less•than•250mA.
3.• The•door•lock•control•is•not•timed•from•Exit•Button(EB).
4.• The•Unlock Mode•Parameter•of•Monitor•must•be•set•to•0•(by•default).

Door Lock Controlled with Dry Contact

•••••Note:

1.• The•external•power•supply•must•be•used•according•to•the•lock.
2.• The•inside•relay•contact•is•restricted•to•AC•or•DC•24V/1A.
3.• The•jumper•must•be•taken•off•before•connecting.
4.• Setup•the•Unlock Mode•of•Monitor•for•different•lock•types.

•• Power-on-to-unlock•type:Unlock•Mode=0•(by•default)
•• Power-off-to-unlock•type:Unlock•Mode=1

EB

*

LOCK

BUS

PL

S1+

S2+

S-

LOCK

2

nd

1

ST

2

nd

EB

*

1

ST

Jumper position in

Connect two locks

2-3

1 2 3

EB

*

LOCK

BUS

PL

S1

+

S2

+

S-

Jumper position in

Connect one lock

2-3

1 2 3