background image

Item

Description

Factory

set

Monitor Timing

To show the monitor time,Range from 6s to 600s

30s

Switch Timing

Reserve

---

Wait Timing

To show the time during which the door station keeps

calling, when door station is making a call, ranging

from 10s to 600s

30s

Talk Timing

To show time available for the conversation when door

station is talking, ranging from 10s to 600s

90s

Monitor & Speak

To enable Indoor Monitor under monitoring state can

speak to Door Station at same time. If set to 1, talk

enabled; set to 0, disabled.

[1]

Monitor & Unlock

To enable Monitors under monitoring state can open

the door at the same time.If set to 0, unlock function

is disabled; Set to 1, unlock is enable;Set to 2,unlock

is enable and close at once;Set to 3,unlock is enable

and close in 5s.

[1]

Ring Numbers

To show ring times when door station calls monitor.4

options for choice. If set to 0, ring once. If set to 1,ring

twice. If set to 2, ring three times.If set to 3,cycle ring

[1]

Name List Mode

To show the namelist display mode.If set to 0,it's the

ST-Config display mode.If set to 1,it's the Simulate

display mode

[0]

Working Mode

Reserve

---

Input Mode

To show the input type when door station makes a call [****1111]

Table 2.1(Parameters):

Note:

this section is set on ST-Config software,for more detail informations,please refer to the

ST-Config software user instructions.